Ivoclar Programat P95 is a high-tech, fully automatic ceramic vacuum furnace designed for dental technology. It is a successor to the Programat P90, featuring improved temperature sensing and microprocessor control. Technical Specifications

| Parameter | Range | Default | Clinical Impact | | :--- | :--- | :--- | :--- | | Heating rate | 1 – 100°C/min | 10°C/min | Too fast cracks green-state ZrO₂. | | Final temp | 800 – 1600°C | 1530°C | ±10°C changes translucency. | | Hold time | 0 – 999 min | 90 min | Insufficient hold = low density. | | Cooling rate (R1/R2) | 1 – 40°C/min | 12°C/min | Too fast = crown cracks. | | Vacuum on/off | On/Off | Off (Sinter) | On = oxygen vacancies (gray). | Ivoclar Programat P95 Manual

Immediate Action Steps:

: Keep the sealing ring (35) and scaling rim (69) clean and undamaged to ensure a proper vacuum seal. Calibration Ivoclar Programat P95 is a high-tech, fully automatic